Open Chamber (OTC-2D)

Open Chamber (OTC-2D)

Description

Improve work ability and accuracy with open chamber

Features of Open Chamber (OTC-2D)

Features
Directly put hands into the chamber to work wide opening
Features
With RS232C I/F. remote controllable by personal computer
Features
It’s loaded with econo-cover which can improve temp. distribution accuracy and temp. rising time.

Additional information

Model

OTC-2D

Operating Functions

Fixed operation, Automatic or manual defrost mode, Repeat function, 16 steps setting for temp. and time (1 to 999min.)

Weight

470kg

Item Code

211399

Type

Air curtain type (3 layers) (triple stream)

Setting temp. range

-30 to +80°C (with econo-cover)

Time to reach

Approx. within 60min. from +25 to -25°C

Time to reach 2

Approx. within 30min. from +25 to +80°C

Temperature control

PID control by microcomputer

Temperature sensor

Pt resistance thermometer

Temperature setting type

Touch panel input on LCD display

Temperature display type

7 segments display on LCD display

Additional Function

Total operation hours timer (to99,999.9hrs.)

External interface

RS232C (Communication function such as temp. setting, Run / Stop, Temp. monitor)

Refrigerator/Coolant

Rotary type/R404A, 1.1kW x 2

Heater capacity

3.0kW

Chamber lightning

15W (Incandescent light)

Cable hole

I.D. 60mm

Safety countermeasures

Abnormal overheat preventor, Abnormal high pressure preventor for compressor, Short-circuit breaker, Motor breaker, Emergency stop switch

Accessories

Econo-cover

Internal dimensions(W×D×H mm)

810×600×600mm

External dimensions(W×D×H mm)

1130×1100×1700mm

Remarks(dimensions)

300L

Power Source

AC220 V/ AC380V
Three-phase with step down transformer