Solvent Recovery Unit (GAS410)

Solvent Recovery Unit (GAS410)

Description

Highly safe N2 gas sealed circulation system, which can be operated with a spray dryer unit

Features of Solvent Recovery Unit (GAS410)

Features
The Inert N2 Gas Sealed System is used to prevent external
discharge when combined with a spray dryer (ADL311SA or
GB-210A) when using an organic solvent.
Features
Dehumidifier (Freezer) integrated in GAS410. No extra Freezer/
dehumidi-fier equipment needed
Features
Compressor included, no need for a separate compressor to operate
the spray dryer ADL311SA when using organic solvent samples
Features
Flammable or toxic solvents can be processed by combining a N2 gas
sealed circulation system and a solvent recovery system (with freezer
and capacitor)
Features
Explosion safety with closed loop N2 inert gas system
Features
Recovery of solvent to protect the environment and enable minimized
pollution.
Features
Drying of easily oxidized materials is possible
Features
Supports low temperature drying of materials that easily deform with
heat
Features
No freezing risk due to organic solvent with aqueous solution mixtures
which could cause damage to the closed loop GAS410 system
Features
Spray drying and recovery of products and solvents are performed with
meticulously devised safety measures

Additional information

Model

GAS410

Solvent recovery mechanism

Capacitor cooling mechanism

Weight

130kg

Solvent recovery system

Capacitor + freezer

Circulating gas

N2 gas (sealed circulation when connected to ADL311SA or GB-210A)

Circulating volume flow

0.12 to 0.65m3/min

Compressor (for spraying)

Linear compressor integrated

Circulation blower

Roots blower

Solvent recovery container

2L flask

Freezer

Air-cooled condensation full-sealed type: 400W R404A (GWP:3920)

Item Code

212774

Instruments

Cooling trap temperature display monitor Filter differential pressure meter (Monitor for clogging of filter) O2 density display monitor Blower wind amount adjusting volume

Filter

Cartridge filter

O2 sensor

Solid electrolyte (Zirconium) limit current type

Pump

For circulation to measure Oxygen

Safety device

O2 density meter, Flammable gas alarm, Electric leakage breaker, N2 gas forced introduction (when removing nozzles)

Required N2 amount

15 L/h at 0.1 MPa

Accessories

Set of connection parts, anti-seismic clamps, interface cable, sample gas for gas alarm inspection, 2L flask

External dimensions(W×D×H mm)

700×950×1500mm

Power Source

AC200-AC240V
Single phase AC200〜240V 5A(15A)