Low Temperature Incubator (Programmable, Peltier Cooling) (IJ101W)

Low Temperature Incubator (Programmable, Peltier Cooling) (IJ101W)

Description

Fixed Temp. Incubator from small to large capacity, high functional and best-selling for long years

Features of Low Temperature Incubator (Programmable, Peltier Cooling) (IJ101W)

Highly functional fixed temp. incubator with varying capacity.
A compact model ideal for preserving samples and for constant temperature testing
Feature
A CFC-free, low-vibration model with a cooler equipped with peltier elements
Feature
Uses a programmable temperature controller (IJ201/300)
Feature
Has a convenient pre-reset temperature function ( as an option)
Feature
Air jacket can be attached as an option
Feature
Two units can be stacked by the stacking support (Option)
Feature
The IJ101W observation window uses environmentally friendly glass made from combination of energy-saving pair glsass and half-tempered glass, which prevents wasteful heat loss
Feature
A sliding mounting table can be provided with the IJ300 model ( as an option) for convenience when setting a microshaker inside and when adding / removing samples. The service outlet on the side of the unit does not require any wiring. A shaker cannot be set in the IJ101W model.
Feature
Safety has been enhanced with the addition of a self-diagnostic function, an overheat prevention device and an over-current circuit breaker.

Additional information

Model

IJ101W

Temp. control method

PID

Cable hole

φ30mm, Right side of the main body

Item Code

221185

Type

Forced convection

Operating Temperature Range

5~60℃(at room temp.25℃)

Temp. control accuracy

±0.3℃(at 37℃)

Temp. distribution accuracy

±1.0℃(at 37℃)

Time to Max. Temp.

20~60℃ 60min.

Time to Lowest Temp.

20~5℃ 100min.

Interior

Stainless steel

Heater

Mica heater 120W

Condenser

Peltiert element, Forced radiation type

Operation function

Program operation (30 steps x 1, 15 steps x 2, 10 steps x 3), Fixed operation, Quick auto-stop, Auto-stop, Auto-start operation

Additional functions

Calibration off-set, Key-lock function, Auto recovery function at power failure

Sensor

Double sensor: Platinum resistance Pt 100Ω (Temp. controller), K-thermocouple(Overheat preventor)

Safety Functions

Self-diagnostic function(Temp. sensor error, heater failure, SSR short-circuit, Auto overheat), Overheat prevention(IJ201/301), Liquid pressure overheat preventor, Over-current ELB, Main relay error

Shelf loading Capacity

Approx. 5kg/ shelf

Shelf Step

7 steps

Accessories

Shelf(Stainless punching metal) 2pcs., Shelf support 4 pcs., Receiver for drain 1pc.

Internal dimensions(W×D×H mm)

250×250×250mm

External dimensions(W×D×H mm)

350×399×565mm

Remarks(dimensions)

15.6L

Power Source

AC115V/AC220V
single phase with step-down transformer

Weight

22kg

Observation window

180 x 180mm